Single Loop Analogue Addressable Control Panel Expandable to 2 Loopsلوحة تحكم انذار حريق ماركه نورتك سينجل لوب
د.إ2,150.00
NGA - 800 is a single loop Analogue Addressable control panel
which can be expanded to two loops. It provides a cost effective
solution for small to medium sized installations. NGA - 800 can
support up to 125 addressable devices on each loops.
Using Nortech advanced communications mechanism, up to
32 individually addressed Loop sounders can be connected to
each of NGA - 800 detection Loops.
The panel is equipped with a backlit LCD display of 4 rows each with 40 characters to give clear textual
indications of fire / fault occurences to the end user. /there are also 16 Zone Fire LED indicators.
NGA - 910 Repeaters and MIni-repeaters can be connected via an RS422/RS485, Fibre Optic or
TCP/IP interface to facilitate remote display and control of the system.
An interactive graphic representation of the system can be displayed on the user’s computer via
NGA-905 graphical software (optional). All the devices on the system can be displayed on a building
plan showing their status in real time. In the event of fire or fault the customer can control the system
and access all the necessary inforamtion with a few mouse-clicks.
Automatic Device Detection at start up reduces time spent at the commissioning stage. In Installation
mode NGA-800 detects and recognises addressed and connected devices with the system being fully
operational in less than two minutes.
The default programming ensures that the system is ready to detect Fire/ Fault alerts from the moment
that power is applied. Additional programming to customise the system can be implemented using a
laptop PC running the NGA - 900 connector software.
NGA – 800 is a single loop Analogue Addressable control panel
which can be expanded to two loops. It provides a cost effective
solution for small to medium sized installations. NGA – 800 can
support up to 125 addressable devices on each loops.
Using Nortech advanced communications mechanism, up to
32 individually addressed Loop sounders can be connected to
each of NGA – 800 detection Loops.
The panel is equipped with a backlit LCD display of 4 rows each with 40 characters to give clear textual
indications of fire / fault occurences to the end user. /there are also 16 Zone Fire LED indicators.
NGA – 910 Repeaters and MIni-repeaters can be connected via an RS422/RS485, Fibre Optic or
TCP/IP interface to facilitate remote display and control of the system.
An interactive graphic representation of the system can be displayed on the user’s computer via
NGA-905 graphical software (optional). All the devices on the system can be displayed on a building
plan showing their status in real time. In the event of fire or fault the customer can control the system
and access all the necessary inforamtion with a few mouse-clicks.
Automatic Device Detection at start up reduces time spent at the commissioning stage. In Installation
mode NGA-800 detects and recognises addressed and connected devices with the system being fully
operational in less than two minutes.
The default programming ensures that the system is ready to detect Fire/ Fault alerts from the moment
that power is applied. Additional programming to customise the system can be implemented using a
laptop PC running the NGA – 900 connector software.