Best Seller Items
-
Fire Hydrant 6”
The pillar hydrant, also sometimes referred to as the dry barrel hydrant, is one of the most visible signs of fire protection measures that can be employed by firefighters. They are placed in the streets for emergency purposes, and are utilized mostly if there is a fire in the immediate vicinity. The pillar hydrant is connected to the area?s water supply, which means that at any given time, the water supply can be utilized through the dry barrel hydrant. If a fire occurs in a place with a hydrant close by, firefighters can easily connect their hose lines to the dry barrel hydrant and use the water in the extinguishing process.
Features
- The dry barrel hydrant is used in case of emergency, so it must always be ready for use.
- The UL FM approved dry barrel hydrant has a 250 PSI pressure.
- Has one pumper nozzle with 4.5-4 NH thread, and two other nozzles with 2.5-7.5 NH threads.
Specifications
- Product: Fire Hydrant
- Brand: Fivalco
د.إ5,700.00Fire Hydrant 6”
د.إ5,700.00 -
Wet fire hydrant
-
Type: Wet Type 2 Way Fire Hydrant
- Size: 4″ & 6″
- Body Material: Cast Iron Bs1452
- Landing Valve Material: Brass or Bronze
- Landing Valve Size: 2 1/2″
- Working Pressure: 16 Bar
- Test Pressure: 30 Bar
- Finish: RAL 3000 Powder Coated
- Inlet: 4″ & 6″ ANSI B Flange
- Outlet: 2 1/2″ Landing Valve Oblique Type with Female Instantaneous Connection
-
-
Landing Valve Fire Hydrant Oblique Screw Type 2.5”
Landing Valve Fire Hydrant Oblique Screw Type 2.5”
د.إ195.00 -
Breeching Inlet 2 way 4 inch
Breeching Inlet 2 way 4 inch
- Inlet : 2.5in BS336 Instantaneous Male c/w Non-Return Valve
- Outlet : 4in PN16 Flange
- Design Pressure : 15 bar
- Test Pressure : 22.5 bar
- Finishing : Red
- Accessories : Plastic Blank Cap with SS Chain
- Gross weight : Approx. 16 kg
د.إ290.00Breeching Inlet 2 way 4 inch
د.إ290.00 -
NON-RISING STEM GATEVALVE – FLANGED
NON-RISING STEM GATEVALVE – FLANGED
Fireguard Valve, resilient wedge designed for optimum performance and incorporates a back-up
seal with the O-ring plate. It features a light weight body with corrossion resistant coating inside &
outside. Wedges is permanently bonded with rubber seal.
* Ductile Iron Body
* Sizes range from 2” to 24”
* OS & Y, NRS
* Fusion Bonded Epoxy Coated Interior and exterior to AWWA C550
* Fully encapsulated disc for bubble tight pressure
* Working pressure 2“ – 10” – 300PSI, 12“-18”- 250 PSI, 20“-24” – 200PSI
* Tapping boss for connection additional devices or measurement
* Corrosion resistanceد.إ399.00NON-RISING STEM GATEVALVE – FLANGED
د.إ399.00 -
SWING CHECK VALVE – GROOVE
Fireguard Check Valve is a compact, rugged swing type unit providing water flow in one direction
and preventing flow in the opposite direction. The valves features a dlight weight ductile iron body
and Stainless steel interior components for superior corrosion resistance. Suitable for vertical and
horizontal instalaltions. The valve is furnished with flanged or grooved ends for ease of installation.
* Ductile Iron Body confirming to ASTM A536
* Flange drilling and dimensions to ANSI B161, 125lb. pattern
* Groove dimensions comply with AWWA C606 standard
* Face to Face dimension conform to AWWA C508
* Working pressure 300 PSI / 350 PSI
* Fusion Bonded Epoxy Coated Interior and exterior to AWWA C550 -
ALARM CHECK VALVE GROOVE / FLANGED
Fireguard Alarm Check valve is a doubled seated clapper check valve with grooved seat design
which ensures positive water flow for alarm operation and is designed for installation in wet pipe
sprinkler system. External bypass prevents false alarm under all supply pressure condition.
In the event of variable pressure condition, false alarm is prevented with the provision of retard
chamber, thus the design allows for isntallation under both variable and constant supply pressure
condition. Operation of one or more automatic fire sprinklers causes the water to flow into the sprinkler
system causing th alarm valve to open, allowing continuous flow of water into the system and transmittal
of alarm, both electrical and mechanical.
* Ductile iron body confirming to ASTM A536
* Double seated clapper design
* Compact design and small foot print
* Smooth operation under variable pressuresد.إ650.00ALARM CHECK VALVE GROOVE / FLANGED
د.إ650.00 -
BUTTERFLY VALVE
The Grooved end and wafer type butterfly valves are indicating type designated for use in
fire protection systems where a visual indication is required as to whether the valve is open
or closed. Valve features a compact and lighter body with factory installed internal switches
having SPDT contacts. The supervisory switches transfer their electrical contacts when there
is movement from the valves normal open position during the first two revolutions of the
handwheel.
* Ductile iron body confirming to ASTM A536
* Poly amide coating
* Fully encapsulated disc for bubble tight pressure
* sizes range 2” – 12“
* working pressure 300 PSI
* Gear box foir easy operation and to reduce torque
* Built – in Supervisory switches for ease of monitoring
* UL listed & FM approved
* Option of ends: Grooved & wafer flanged groovedد.إ780.00BUTTERFLY VALVE
د.إ780.00 -
Upright Sprinkler Quick Response, K-5.6, 79 Deg, Chrome Finish, UL/FM Approved
Description
Fesco PI311 Upright Sprinkler Quick Response, K-5.6, 79 Deg, Chrome Finish, UL/FM Approved. Atlanta FESCO Quick Response Type Sprinkler reacts to heat faster than any regular sprinkler ideally designed for in populated areas where mass human loss or injuries can be occured such as schools, hospitals, office buildings, hotels, restaurants, auditoriums and other facilities with similar occupancy.
Features
- The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to 10mm of vertical
- Continued heating of the exposed sprinkler causes the heat sensitive liquid in the glass bulb to expand and the bulb to shatter
- when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches
- Water flowing through the sprinkler orifice strikes the sprinkler deflector
- Thermosensitive glass-bulb spray sprinklers with the cover plate
- Uniform spray pattern to extinguish or control the fire
Specifications
- Product: Upright Sprinkler
- Brand: Atlanta
- Model: PI311
- Working Temperature: 68ºC (155ºF)
- Max Ambient Temp: 65ºC (150ºF)
- Connection Screw Size: NPT 1/2″
- Orifice Size: Ø57.0mm
- Maximum Working Pressure: 175psi (1.23Mpa)
د.إ59.00 -
Frontier Upright Sprinkler
Description
Frontier Upright Sprinkler 68 Degrees Quick Response UL Listed designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13). The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb. The sprinklers come with a compact design. available in different finishes and temperature ratings.
Features
- Designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13)
- The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb
- Available in different finishes and temperature ratings
- Sprinklers come with compact design
Specifications
- Product: Upright Sprinkler
- Brand: Frontier
- Model: FN004
- Finish: Brass and chrome plated and white plated available
- K Factor: 5.6
- Size: 1/2 Inch
د.إ57.00Frontier Upright Sprinkler
د.إ57.00 -
Upright Sprinkler Standard Response, K-5.6, 79 Deg, Brass Finish, UL/FM Approved
Specifications
- Product: Upright Sprinkler
- Model: PI310
- Working Temperature: 68ºC (155ºF)
- Max Ambient Temp: 65ºC (150ºF)
- Connection Screw Size: NPT 1/2″
- Orifice Size: Ø57.0mm
- Maximum Working Pressure: 175psi (1.23Mpa)
د.إ56.00 -
Upright Quick Response Sprinkler, Brass Finish
Upright Quick Response Sprinkler, Brass Finish, 68’C frangible glass bulb automatic sprinklers that are CE, VdS and LPCB approved. They are standard orifice fire sprinklers for installation in fire sprinkler systems designed in accordance with standard installation rules, e.g. EN12845 or the requirements of the authority having jurisdiction.
SSU Upright sprinklers produce a hemispherical water distribution pattern below the deflector. In the instance of fire, the heat causes the fluid in the glass bulb to expand which shatters the glass and releases the spring seal assembly. Water flows from the orifice onto the sprinkler deflector which diffuses the water into a uniform spray pattern which extinguishes or controls the fire
د.إ55.00