• METACAULK Fire Barrier Sealant

    Brand:METACAULK
    BrandMETACAULK
    Application MethodCaulk Gun
    ColorRed
    Container Size5 gal
    Container TypePail
    Coverage Area1.08 cu ft
    Density12.5 lb/gal
    Drying Time30 min @ 77°F
    ElastomericYes
    Expansion Temperature300 °F
    Expansion Volume25X
    Fire Rating4 hr
    Fire Resistance TypeIntumescent
    Firestop TypeSealant/Caulk
    Flame Spread Index10
    Flame Spread RatingClass A
    For LocationThrough Penetrations; Construction Joints
    For Material TypeConcrete; Gypsum; Metal; Wood
    For Use OnPower and Communication Cables; Wall Construction Joints
    FormulationWater Based
    IntumescentYes
    Maximum Service Temperature120 °F
    Non-SaggingYes
    PaintableYes
    STC Rating65
    SeriesMetacaulk 150+
    Shelf Life3 yr
    Smoke Developed Index0
    StandardsASTM E1966 (UL 2079); ASTM E814 (UL 1479); FM Approved
    Usage LocationWall Construction Joints
    Water ActivatedYes
    WatertightNo
    Color FamilyRed
    CompositionSilicone
    Usage LocationConstruction Joints
    Brand & SeriesMETACAULK Metacaulk 150+
    Container Size & Type5 gal Pail
    Manufacturer Part Number66389
    SeriesMetacaulk 150+
    Sub-brandFire Stop
    Firestop Material TypeCaulk
    New PropertiesYes NS x Yes E x Yes In
    PropertiesNon-Slump; Elastomeric; Intumescent
    PropertiesNon-Slumping; Intumescent; Elastomeric
    UNSPSC46191503
    Country of OriginUSA (subject to change)
  • Breeching Inlet 2 way 4 inch

    Breeching Inlet 2 way 4 inch

    • Inlet : 2.5in BS336 Instantaneous Male c/w Non-Return Valve
    • Outlet : 4in PN16 Flange
    • Design Pressure : 15 bar
    • Test Pressure : 22.5 bar
    • Finishing : Red
    • Accessories : Plastic Blank Cap with SS Chain
    • Gross weight : Approx. 16 kg

     

  • NON-RISING STEM GATEVALVE – FLANGED

    NON-RISING STEM GATEVALVE – FLANGED
    Fireguard Valve, resilient wedge designed for optimum performance and incorporates a back-up
    seal with the O-ring plate. It features a light weight body with corrossion resistant coating inside &
    outside. Wedges is permanently bonded with rubber seal.
    * Ductile Iron Body
    * Sizes range from 2” to 24”
    * OS & Y, NRS
    * Fusion Bonded Epoxy Coated Interior and exterior to AWWA C550
    * Fully encapsulated disc for bubble tight pressure
    * Working pressure 2“ – 10” – 300PSI, 12“-18”- 250 PSI, 20“-24” – 200PSI
    * Tapping boss for connection additional devices or measurement
    * Corrosion resistance

  • SWING CHECK VALVE – GROOVE

    Fireguard Check Valve is a compact, rugged swing type unit providing water flow in one direction
    and preventing flow in the opposite direction. The valves features a dlight weight ductile iron body
    and Stainless steel interior components for superior corrosion resistance. Suitable for vertical and
    horizontal instalaltions. The valve is furnished with flanged or grooved ends for ease of installation.
    * Ductile Iron Body confirming to ASTM A536
    * Flange drilling and dimensions to ANSI B161, 125lb. pattern
    * Groove dimensions comply with AWWA C606 standard
    * Face to Face dimension conform to AWWA C508
    * Working pressure 300 PSI / 350 PSI
    * Fusion Bonded Epoxy Coated Interior and exterior to AWWA C550

  • ALARM CHECK VALVE GROOVE / FLANGED

    Fireguard Alarm Check valve is a doubled seated clapper check valve with grooved seat design
    which ensures positive water flow for alarm operation and is designed for installation in wet pipe
    sprinkler system. External bypass prevents false alarm under all supply pressure condition.
    In the event of variable pressure condition, false alarm is prevented with the provision of retard
    chamber, thus the design allows for isntallation under both variable and constant supply pressure
    condition. Operation of one or more automatic fire sprinklers causes the water to flow into the sprinkler
    system causing th alarm valve to open, allowing continuous flow of water into the system and transmittal
    of alarm, both electrical and mechanical.
    * Ductile iron body confirming to ASTM A536
    * Double seated clapper design
    * Compact design and small foot print
    * Smooth operation under variable pressures

  • BUTTERFLY VALVE

    The Grooved end and wafer type butterfly valves are indicating type designated for use in
    fire protection systems where a visual indication is required as to whether the valve is open
    or closed. Valve features a compact and lighter body with factory installed internal switches
    having SPDT contacts. The supervisory switches transfer their electrical contacts when there
    is movement from the valves normal open position during the first two revolutions of the
    handwheel.
    * Ductile iron body confirming to ASTM A536
    * Poly amide coating
    * Fully encapsulated disc for bubble tight pressure
    * sizes range 2” – 12“
    * working pressure 300 PSI
    * Gear box foir easy operation and to reduce torque
    * Built – in Supervisory switches for ease of monitoring
    * UL listed & FM approved
    * Option of ends: Grooved & wafer flanged grooved

    BUTTERFLY VALVE

    د.إ780.00
  • Frontier Upright Sprinkler

    Description

    Frontier  Upright Sprinkler 68 Degrees Quick Response UL Listed designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13). The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb. The sprinklers come with a compact design. available in different finishes and temperature ratings.

    Features

    • Designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13)
    • The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb
    • Available in different finishes and temperature ratings
    • Sprinklers come with compact design

    Specifications

    • Product: Upright Sprinkler
    • Brand: Frontier
    • Model: FN004
    • Finish: Brass and chrome plated and white plated available
    • K Factor: 5.6
    • Size: 1/2 Inch
  • Nortech Addressable Photoelectric Smoke Detector

    Brand:Nortech

    The NGA-401 Analogue Addressable Photoelectric Smoke
    Detector have been designed to be fully compatible with the
    Nortech Global range of intelligent control panels.
    Compliant to EN54-5 and 7, the NGA series detectors are available in Optical, Heat and combined Smoke/Heat detector
    versions.. Optionally they can be fitted with a short-circuit loop
    isolator.
    FEATURES
    ► Dual LEDs for 360° visibility
    ► Advance detection and communication protocols
    ► Easy installation and maintenance
    ► Sleek low-profile housing
    ► Durable sensor head, no need for replacement
    ► SMD circuit board design. High quality and reliability guaranteed

  • Single Loop Analogue Addressable Control Panel Expandable to 2 Loopsلوحة تحكم انذار حريق ماركه نورتك سينجل لوب

    Brand:Nortech

    NGA – 800 is a single loop Analogue Addressable control panel
    which can be expanded to two loops. It provides a cost effective
    solution for small to medium sized installations. NGA – 800 can
    support up to 125 addressable devices on each loops.
    Using Nortech advanced communications mechanism, up to
    32 individually addressed Loop sounders can be connected to
    each of NGA – 800 detection Loops.
    The panel is equipped with a backlit LCD display of 4 rows each with 40 characters to give clear textual
    indications of fire / fault occurences to the end user. /there are also 16 Zone Fire LED indicators.
    NGA – 910 Repeaters and MIni-repeaters can be connected via an RS422/RS485, Fibre Optic or
    TCP/IP interface to facilitate remote display and control of the system.
    An interactive graphic representation of the system can be displayed on the user’s computer via
    NGA-905 graphical software (optional). All the devices on the system can be displayed on a building
    plan showing their status in real time. In the event of fire or fault the customer can control the system
    and access all the necessary inforamtion with a few mouse-clicks.
    Automatic Device Detection at start up reduces time spent at the commissioning stage. In Installation
    mode NGA-800 detects and recognises addressed and connected devices with the system being fully
    operational in less than two minutes.
    The default programming ensures that the system is ready to detect Fire/ Fault alerts from the moment
    that power is applied. Additional programming to customise the system can be implemented using a
    laptop PC running the NGA – 900 connector software.

  • Nortech Addressable Wall Mount Sounder/Beacon

    Brand:Nortech

    The NGA-504 ASB is a wall mounted Addressable Sounder /
    Beacon with low power consumption. Up to 32 individually
    addressed sounders can be installed per loop occupying
    address 94 to 125. The address is set using switches 1 to 5 of
    the 8 way DIL switch. Four different tones are available and
    selected using DIL switches 6 and 7.
    SPECIFICATION
    When individual address reporting is not required, NGA-504 ASB can be configured as a Shadow
    sounder. In this case sounders do not occupy and address i nthe loop thus freeing up addresses for
    more detection devices. Shadow sounders do not report back to the control panel so their presence on
    the loop is not monitored. Shadow sounders draw current from the loop (10mA in alarm) and must be
    included in loop load calculations.

  • Nortech Addressable Manual Call Pointنورتك نقطة نداء ادريسبل

    Brand:Nortech

    OVERVIEW
    NGA-501 is an Analogue Addressable Manual CAll Point,
    designed and manufactured comply with EN54-11, compatible
    with Nortech Addressable Control Panels. With its enhance
    commuication mechanism the typical response time, when in
    alarm is approximately one second, depending on the number
    of call points connected to the device loop.
    A bi-colour LED flashes Green when the unit is interrogated by the control panel and is illuminate Red
    when in alarm. The command to illuminate the Red LED is emitted by the control panel in response to
    activation of the individual call point thus confirming that the alarm signal has been received at control
    panel.