• Nortech Addressable Photoelectric Smoke Detector

    Brand:Nortech

    The NGA-401 Analogue Addressable Photoelectric Smoke
    Detector have been designed to be fully compatible with the
    Nortech Global range of intelligent control panels.
    Compliant to EN54-5 and 7, the NGA series detectors are available in Optical, Heat and combined Smoke/Heat detector
    versions.. Optionally they can be fitted with a short-circuit loop
    isolator.
    FEATURES
    ► Dual LEDs for 360° visibility
    ► Advance detection and communication protocols
    ► Easy installation and maintenance
    ► Sleek low-profile housing
    ► Durable sensor head, no need for replacement
    ► SMD circuit board design. High quality and reliability guaranteed

  • Nortech Addressable Manual Call Pointنورتك نقطة نداء ادريسبل

    Brand:Nortech

    OVERVIEW
    NGA-501 is an Analogue Addressable Manual CAll Point,
    designed and manufactured comply with EN54-11, compatible
    with Nortech Addressable Control Panels. With its enhance
    commuication mechanism the typical response time, when in
    alarm is approximately one second, depending on the number
    of call points connected to the device loop.
    A bi-colour LED flashes Green when the unit is interrogated by the control panel and is illuminate Red
    when in alarm. The command to illuminate the Red LED is emitted by the control panel in response to
    activation of the individual call point thus confirming that the alarm signal has been received at control
    panel.
    The unit is supplied complete with hinged flap which protects the trigger element from accidental activation and reduces malicious activations as two actions are required in order to activate device. this
    unit can be booth surface and flush mounted and it can be easily reset using the supplied key after activation.

  • Nortech Addressable Wall Mount Sounder/Beacon

    Brand:Nortech

    The NGA-504 ASB is a wall mounted Addressable Sounder /
    Beacon with low power consumption. Up to 32 individually
    addressed sounders can be installed per loop occupying
    address 94 to 125. The address is set using switches 1 to 5 of
    the 8 way DIL switch. Four different tones are available and
    selected using DIL switches 6 and 7.
    SPECIFICATION
    When individual address reporting is not required, NGA-504 ASB can be configured as a Shadow
    sounder. In this case sounders do not occupy and address i nthe loop thus freeing up addresses for
    more detection devices. Shadow sounders do not report back to the control panel so their presence on
    the loop is not monitored. Shadow sounders draw current from the loop (10mA in alarm) and must be
    included in loop load calculations.

  • Nortech Fire alarm control panel نورتك لوحة تحكم انذار الحريق

    Brand:Nortech

    NGA-600 is a powerful Analogue Addressable Fire Alarm Control Panel with networking capabilities that facilitate the configuration of complex Wide Area Fire Detection Systems. Modular
    construction and distributed intelligence allow systems of up to
    96 loops to be constructed. With a High level built-in redundancy and emergency back-up features, the NGA-600 is fully
    equipped to control the most complex isntallations.
    Using its wide array of interfacing capabilities the NGA-600 is ideally placed to provide an efficient and effective solution to the logistics of protecting large institution.
    NGA-600 is available as a standalone system of up to 13 loops in a single cabinet
    and can be expanded to up to 96 loops via a networked array of sub-panels which
    can be supplied in a blank box version or combined with a repeater to allow remote
    display and control of the system. Networking is done by a monitored, redundant,
    double RS422/RS485, Fibre optic loop or TCP/IP network.

  • Single Loop Analogue Addressable Control Panel Expandable to 2 Loopsلوحة تحكم انذار حريق ماركه نورتك سينجل لوب

    Brand:Nortech

    NGA – 800 is a single loop Analogue Addressable control panel
    which can be expanded to two loops. It provides a cost effective
    solution for small to medium sized installations. NGA – 800 can
    support up to 125 addressable devices on each loops.
    Using Nortech advanced communications mechanism, up to
    32 individually addressed Loop sounders can be connected to
    each of NGA – 800 detection Loops.
    The panel is equipped with a backlit LCD display of 4 rows each with 40 characters to give clear textual
    indications of fire / fault occurences to the end user. /there are also 16 Zone Fire LED indicators.
    NGA – 910 Repeaters and MIni-repeaters can be connected via an RS422/RS485, Fibre Optic or
    TCP/IP interface to facilitate remote display and control of the system.
    An interactive graphic representation of the system can be displayed on the user’s computer via
    NGA-905 graphical software (optional). All the devices on the system can be displayed on a building
    plan showing their status in real time. In the event of fire or fault the customer can control the system
    and access all the necessary inforamtion with a few mouse-clicks.
    Automatic Device Detection at start up reduces time spent at the commissioning stage. In Installation
    mode NGA-800 detects and recognises addressed and connected devices with the system being fully
    operational in less than two minutes.
    The default programming ensures that the system is ready to detect Fire/ Fault alerts from the moment
    that power is applied. Additional programming to customise the system can be implemented using a
    laptop PC running the NGA – 900 connector software.